Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 32
Page 15
... persons shall be punishable by a fine of not more than $ 300 , or by impris- onment for not more than 90 days , or by both such fine and im- prisonment . CHAPTER 3 - PERMITS AND INSPECTIONS Sec . 301. ( a ) Permits Required . No person ...
... persons shall be punishable by a fine of not more than $ 300 , or by impris- onment for not more than 90 days , or by both such fine and im- prisonment . CHAPTER 3 - PERMITS AND INSPECTIONS Sec . 301. ( a ) Permits Required . No person ...
Page 43
... persons ) . Hospitals , sanitariums , nursing homes with nonambulatory pa- tients and similar buildings ( each accommodating more than five persons ) . Division 3. Nursing homes for ambulatory patients , homes for children of ...
... persons ) . Hospitals , sanitariums , nursing homes with nonambulatory pa- tients and similar buildings ( each accommodating more than five persons ) . Division 3. Nursing homes for ambulatory patients , homes for children of ...
Page 140
... persons are to be accommodated within such an area , there shall be a minimum of three exits , and for more than 9000 persons there shall be at least four exits . The aggregate clear width of exits from a safe dispersal area shall be ...
... persons are to be accommodated within such an area , there shall be a minimum of three exits , and for more than 9000 persons there shall be at least four exits . The aggregate clear width of exits from a safe dispersal area shall be ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles