Page 47
... pipe Systems inlets shall be installed as specified in Chapter 38 of the 1967 Edi- tion of the Uniform Building Code ... piping , and shafting . All openings in exterior walls except wall vents shall be protected by a fire assembly ...
... pipe Systems inlets shall be installed as specified in Chapter 38 of the 1967 Edi- tion of the Uniform Building Code ... piping , and shafting . All openings in exterior walls except wall vents shall be protected by a fire assembly ...
Page 74
... pipes shall be so framed and the joists underneath so spaced as to give proper clearance for the piping . Where a partition containing such piping runs parallel to the floor joists , the joists underneath such partitions shall be ...
... pipes shall be so framed and the joists underneath so spaced as to give proper clearance for the piping . Where a partition containing such piping runs parallel to the floor joists , the joists underneath such partitions shall be ...
Page 76
... Pipes and Conduits Embedded in Masonry . No pipe or conduit shall be embedded in any structural masonry necessary for structural stability or required fire protection . EXCEPTIONS : 1. Rigid electric conduits may be em- bedded in ...
... Pipes and Conduits Embedded in Masonry . No pipe or conduit shall be embedded in any structural masonry necessary for structural stability or required fire protection . EXCEPTIONS : 1. Rigid electric conduits may be em- bedded in ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles