Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 10
Page 101
... portland cement plaster . PORTLAND CEMENT PLASTER is a mixture of portland ce- ment , or portland cement and lime and aggregate and other ap- proved materials as specified in this Code . STRIPPING is flat reinforcing units of expanded ...
... portland cement plaster . PORTLAND CEMENT PLASTER is a mixture of portland ce- ment , or portland cement and lime and aggregate and other ap- proved materials as specified in this Code . STRIPPING is flat reinforcing units of expanded ...
Page 107
... portland cement plaster shall be furred out away from vertical supports at least one - fourth inch ( 4 " ) . Self - furring lath meets furring requirement . Exception : Furring is not required on steel supports having a flange width of ...
... portland cement plaster shall be furred out away from vertical supports at least one - fourth inch ( 4 " ) . Self - furring lath meets furring requirement . Exception : Furring is not required on steel supports having a flange width of ...
Page 110
... portland cement plaster . Backing is not required under metal lath or paperbacked wire lath . ( d ) Weather Protection . Building paper shall be installed as required in Section 1707 ( a ) . ( e ) Application of Metal Plaster Bases ...
... portland cement plaster . Backing is not required under metal lath or paperbacked wire lath . ( d ) Weather Protection . Building paper shall be installed as required in Section 1707 ( a ) . ( e ) Application of Metal Plaster Bases ...
Contents
Part IAdministrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet 1 hour feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches G Occupancies gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles