Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 15
Page 76
... Reinforced Grouted Masonry Reinforced Hollow Unit Masonry REBEKK 10 16 14 16 18 18 25 25 66888766 NONBEARING WALLS : Exterior Unreinforced Walls Exterior Reinforced Walls 2883 20 30 36 48 2222 Interior Partitions Unreinforced Interior ...
... Reinforced Grouted Masonry Reinforced Hollow Unit Masonry REBEKK 10 16 14 16 18 18 25 25 66888766 NONBEARING WALLS : Exterior Unreinforced Walls Exterior Reinforced Walls 2883 20 30 36 48 2222 Interior Partitions Unreinforced Interior ...
Page 96
... reinforced concrete not less than eight inches ( 8 " ) thick , except that stone masonry shall be not less than twelve inches ( 12 " ) thick ; and , in addition , shall be lined with not less than four inches ( 4 " ) of firebrick laid ...
... reinforced concrete not less than eight inches ( 8 " ) thick , except that stone masonry shall be not less than twelve inches ( 12 " ) thick ; and , in addition , shall be lined with not less than four inches ( 4 " ) of firebrick laid ...
Page 100
... reinforcing bars conforming to the provisions of Chapter 24 or 26 , 1967 Edition , Uniform Building Code , Volume I ... reinforce the corners of interior surfaces . CORNERITE is a shaped reinforcing unit of expanded metal or wire fabric ...
... reinforcing bars conforming to the provisions of Chapter 24 or 26 , 1967 Edition , Uniform Building Code , Volume I ... reinforce the corners of interior surfaces . CORNERITE is a shaped reinforcing unit of expanded metal or wire fabric ...
Contents
Part IAdministrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet 1 hour feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches G Occupancies gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles