Page 36
... roof soffit provided the roof is of at least two - hour fire - resistive construction . 2. Two - hour area separation walls may terminate at the underside of roof sheathing provided that the roof has at least one - hour fire - resistive ...
... roof soffit provided the roof is of at least two - hour fire - resistive construction . 2. Two - hour area separation walls may terminate at the underside of roof sheathing provided that the roof has at least one - hour fire - resistive ...
Page 87
... Roof Coverings roof covering shall be any one of the following roofings : 1. Any Class A or B built - up roofing assembly . 2. Any mineral aggregate surfaced built - up roof for application to roofs having a slope not more than three ...
... Roof Coverings roof covering shall be any one of the following roofings : 1. Any Class A or B built - up roofing assembly . 2. Any mineral aggregate surfaced built - up roof for application to roofs having a slope not more than three ...
Page 89
... Roof Coverings split sheet , or ( Continued ) One layer of 80 - pound mineral surfaced asbestos fiber felt cap sheet ... roof . 8. Metal roof covering . 9. Slate shingles . 10. Clay or concrete roof tile . ( b ) Ordinary Roof Covering ...
... Roof Coverings split sheet , or ( Continued ) One layer of 80 - pound mineral surfaced asbestos fiber felt cap sheet ... roof . 8. Metal roof covering . 9. Slate shingles . 10. Clay or concrete roof tile . ( b ) Ordinary Roof Covering ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles