Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 35
Page 28
... Separation . Occupancy separations shall be classed as " Four - Hour Fire - Resistive , " " Three - Hour Fire ... Separation " shall have no openings therein and shall be of not less than four - hour fire - resistive construction . 2. A ...
... Separation . Occupancy separations shall be classed as " Four - Hour Fire - Resistive , " " Three - Hour Fire ... Separation " shall have no openings therein and shall be of not less than four - hour fire - resistive construction . 2. A ...
Page 29
... Separation Walls . Each portion of a building separated by one or more area separation walls may be considered a separate building provided the area separation walls meet the following requirements : 1. Area separation walls shall be ...
... Separation Walls . Each portion of a building separated by one or more area separation walls may be considered a separate building provided the area separation walls meet the following requirements : 1. Area separation walls shall be ...
Page 36
... separation walls shall extend from the foundation to a point at least thirty inches ( 30 " ) above the roof . EXCEPTIONS : 1. Area separation walls may terminate at the roof soffit provided the roof is of at least two - hour fire ...
... separation walls shall extend from the foundation to a point at least thirty inches ( 30 " ) above the roof . EXCEPTIONS : 1. Area separation walls may terminate at the roof soffit provided the roof is of at least two - hour fire ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles