Page 83
Studs or sheathing shall be covered on Exterior Wall the outside face with one
layer of building paper when required Coverings in Section 1707 ( a ) . (
Continued ) Weatherboarding shall have an average thickness in place of not
less than ...
Studs or sheathing shall be covered on Exterior Wall the outside face with one
layer of building paper when required Coverings in Section 1707 ( a ) . (
Continued ) Weatherboarding shall have an average thickness in place of not
less than ...
Page 92
Each wood shingle shall be fastened to the sheathing with two nails only .
Shingles shall not be installed on a roof having a slope less than four inches ( 4 "
) to twelve inches ( 12 " ) unless they are installed over an underlay of not less
than 15 ...
Each wood shingle shall be fastened to the sheathing with two nails only .
Shingles shall not be installed on a roof having a slope less than four inches ( 4 "
) to twelve inches ( 12 " ) unless they are installed over an underlay of not less
than 15 ...
Page 119
Gypsum lath and ( Continued ) plaster , gypsum sheathing board , and gypsum
wallboard shall not be used in vertical diaphragms to resist forces imposed by
masonry or concrete construction . ( c ) Wall Framing . Framing for vertical ...
Gypsum lath and ( Continued ) plaster , gypsum sheathing board , and gypsum
wallboard shall not be used in vertical diaphragms to resist forces imposed by
masonry or concrete construction . ( c ) Wall Framing . Framing for vertical ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part Administrative | 11 |
Part 11Definitions and Abbreviations | 20 |
Part IIlRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood