... sheathing which con- forms to the provisions specified in Section 2202 , 1967 Edition of the Uniform Building Code , Volume I. All weatherboarding or siding shall be securely nailed to each stud with not less than one nail , or to solid ...
... sheathing which con- forms to the provisions specified in Section 2202 , 1967 Edition of the Uniform Building Code , Volume I. All weatherboarding or siding shall be securely nailed to each stud with not less than one nail , or to solid ...
Page 92
... sheathing with two nails only . Shingles shall not be installed on a roof having a slope less than four inches ( 4 ... sheathing . The spaced sheathing shall be spaced not to exceed four inches ( 4 " ) clear nor more than the width of ...
... sheathing with two nails only . Shingles shall not be installed on a roof having a slope less than four inches ( 4 ... sheathing . The spaced sheathing shall be spaced not to exceed four inches ( 4 " ) clear nor more than the width of ...
Page 119
... sheathing board , and gypsum wallboard shall not be used in vertical diaphragms to resist forces imposed by masonry or concrete construction . ( c ) Wall Framing . Framing for vertical diaphragms shall com- ply with Section 2507 ( b ) ...
... sheathing board , and gypsum wallboard shall not be used in vertical diaphragms to resist forces imposed by masonry or concrete construction . ( c ) Wall Framing . Framing for vertical diaphragms shall com- ply with Section 2507 ( b ) ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles