Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 35
Page 39
... space , shall be separated from such space by not less than one - hour fire - resistive construction . For attic space partitions and draft stops see Section 2205 . ( c ) Division 4 Provisions . Erection and structural maintenance of ...
... space , shall be separated from such space by not less than one - hour fire - resistive construction . For attic space partitions and draft stops see Section 2205 . ( c ) Division 4 Provisions . Erection and structural maintenance of ...
Page 78
... space with a maximum of eight inches ( 8 " ) whichever is greater . 4. If the work is stopped for one hour or longer ... space . The cleanout shall be sealed after inspection and before grouting . 4. The grout space ( longitudinal ...
... space with a maximum of eight inches ( 8 " ) whichever is greater . 4. If the work is stopped for one hour or longer ... space . The cleanout shall be sealed after inspection and before grouting . 4. The grout space ( longitudinal ...
Page 94
... space by ventilating openings protected against the en- trance of rain and snow . The net free ventilating ceiling area shall be not less than 1/150 of the area of the space ventilated , except that the area may be 1/300 provided at ...
... space by ventilating openings protected against the en- trance of rain and snow . The net free ventilating ceiling area shall be not less than 1/150 of the area of the space ventilated , except that the area may be 1/300 provided at ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles