Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 8
Page 84
... SPANS FOR PLYWOOD FLOOR AND ROOF SHEATHING CONTINUOUS OVER TWO OR MORE SPANS AND FACE GRAIN PERPENDICULAR TO SUPPORTS ' ROOF2 PANEL IDENTIFICATION Maximum Span LOAD ( IN POUNDS PER INDEX3 ( in Inches ) SQUARE FOOT ) FLOOR Maximum Edges ...
... SPANS FOR PLYWOOD FLOOR AND ROOF SHEATHING CONTINUOUS OVER TWO OR MORE SPANS AND FACE GRAIN PERPENDICULAR TO SUPPORTS ' ROOF2 PANEL IDENTIFICATION Maximum Span LOAD ( IN POUNDS PER INDEX3 ( in Inches ) SQUARE FOOT ) FLOOR Maximum Edges ...
Page 85
... Span lengths for stress - graded lumber as set forth in Tables No. 25 - A and No. 25 - B ° may be based on the stresses therein . Spans in Group I are suitable for any species of stress - graded lumber given in Table No. 25 - A or No ...
... Span lengths for stress - graded lumber as set forth in Tables No. 25 - A and No. 25 - B ° may be based on the stresses therein . Spans in Group I are suitable for any species of stress - graded lumber given in Table No. 25 - A or No ...
Page 87
... span . 1Species of lumber are divided into groups as described in Section 1801 ( a ) . Span lengths for stress - graded lumber as described in Section 1801 ( a ) may be based on the stresses therein . Spans in Group I are suitable for ...
... span . 1Species of lumber are divided into groups as described in Section 1801 ( a ) . Span lengths for stress - graded lumber as described in Section 1801 ( a ) may be based on the stresses therein . Spans in Group I are suitable for ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood