Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 45
Page 37
... specified in Section 505 may be tripled in one - story buildings and doubled in buildings of more than one story if the building is provided with an approved automatic fire - extinguishing system throughout as specified in Chapter 38 of ...
... specified in Section 505 may be tripled in one - story buildings and doubled in buildings of more than one story if the building is provided with an approved automatic fire - extinguishing system throughout as specified in Chapter 38 of ...
Page 40
... Defined natural or artificial light , ventilation , and sanitary facilities as specified in Section 605 of the 1967 Edition of the Uniform Build- ing Code , Volume I , and Section 1711 of this Code . Sec . 706. Exits shall be enclosed as ...
... Defined natural or artificial light , ventilation , and sanitary facilities as specified in Section 605 of the 1967 Edition of the Uniform Build- ing Code , Volume I , and Section 1711 of this Code . Sec . 706. Exits shall be enclosed as ...
Page 44
... determined by location on property , see Section 504 and Part V. Sec . 904. Stairs , exits , and smokeproof enclosures shall be pro- vided as specified in Chapter 25. ( See also Section 2518. ) Sec . 905. All portions of Group D ...
... determined by location on property , see Section 504 and Part V. Sec . 904. Stairs , exits , and smokeproof enclosures shall be pro- vided as specified in Chapter 25. ( See also Section 2518. ) Sec . 905. All portions of Group D ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles