Page 37
... specified in Section 505 may be tripled in one - story buildings and doubled in buildings of more than one story if the building is provided with an approved automatic fire - extinguishing system throughout as specified in Chapter 38 of ...
... specified in Section 505 may be tripled in one - story buildings and doubled in buildings of more than one story if the building is provided with an approved automatic fire - extinguishing system throughout as specified in Chapter 38 of ...
Page 52
... specified in Chapter 38 of the 1967 Edition of the Uniform Building Code ... Section 2501 . Sec . 1202. ( a ) General . Buildings or parts of buildings ... specified in Sections 505 , 506 , and 507 . ( b ) Special Provisions . Fire ...
... specified in Chapter 38 of the 1967 Edition of the Uniform Building Code ... Section 2501 . Sec . 1202. ( a ) General . Buildings or parts of buildings ... specified in Sections 505 , 506 , and 507 . ( b ) Special Provisions . Fire ...
Page 61
... specified in Section 2203. See Section 104 ( f ) for repairs . 4. Such building may be moved entirely outside the limits of Fire Zone No. 1 . 5. Such building may be demolished . ( c ) Occupancies Prohibited . No Group E , Division 2 ...
... specified in Section 2203. See Section 104 ( f ) for repairs . 4. Such building may be moved entirely outside the limits of Fire Zone No. 1 . 5. Such building may be demolished . ( c ) Occupancies Prohibited . No Group E , Division 2 ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles