Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 51
Page 56
... square feet ( 150 sq . ft . ) of superficial floor area . Other habitable rooms shall have an area of not less than ninety square feet ( 90 sq . ft . ) . Where more than two persons occupy a room used for sleeping purposes , the ...
... square feet ( 150 sq . ft . ) of superficial floor area . Other habitable rooms shall have an area of not less than ninety square feet ( 90 sq . ft . ) . Where more than two persons occupy a room used for sleeping purposes , the ...
Page 58
... square feet ( 150 sq . ft . ) of superficial floor area . Other habitable rooms shall have an area of not less than ninety square feet ( 90 sq . ft . ) . Where more than two persons occupy a room used for sleeping purposes the required ...
... square feet ( 150 sq . ft . ) of superficial floor area . Other habitable rooms shall have an area of not less than ninety square feet ( 90 sq . ft . ) . Where more than two persons occupy a room used for sleeping purposes the required ...
Page 85
... square foot - plus weight of joists ; eight pounds per square foot - weight of lath and plaster ; Deflection with or without plaster - Not to exceed 1 / 360th of the span with live load nor 1 / 240th with dead load and live load ...
... square foot - plus weight of joists ; eight pounds per square foot - weight of lath and plaster ; Deflection with or without plaster - Not to exceed 1 / 360th of the span with live load nor 1 / 240th with dead load and live load ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood