Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 13
Page 128
... stairway shall be protected as required for cor- ridors . Other openings to an exterior exit balcony need not be pro- tected unless required by other provisions of this Code . Sec . 2505. ( a ) General . Every stairway serving any ...
... stairway shall be protected as required for cor- ridors . Other openings to an exterior exit balcony need not be pro- tected unless required by other provisions of this Code . Sec . 2505. ( a ) General . Every stairway serving any ...
Page 130
... stairway , ramp , or escala- tor shall be enclosed as specified in this Section . EXCEPTIONS : 1. In other than Group D Occupancies , an enclosure will not be required for a stairway , ramp , or escalator serving only one adjacent floor ...
... stairway , ramp , or escala- tor shall be enclosed as specified in this Section . EXCEPTIONS : 1. In other than Group D Occupancies , an enclosure will not be required for a stairway , ramp , or escalator serving only one adjacent floor ...
Page 131
... Stairway and ramp enclosures shall include landings and parts of floors connecting stairway flights and also shall include a corridor on the ground floor leading from the stairway to the exterior of the building . Enclosed corridors or ...
... Stairway and ramp enclosures shall include landings and parts of floors connecting stairway flights and also shall include a corridor on the ground floor leading from the stairway to the exterior of the building . Enclosed corridors or ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles