Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 13
Page 128
Stairways Sec . 2505 . ( a ) General . Every stairway serving any building or
portion thereof shall conform to the requirements of this ... Stairways serving an
occupant load of more than 50 shall be not less in width than forty - four inches (
44 " ) .
Stairways Sec . 2505 . ( a ) General . Every stairway serving any building or
portion thereof shall conform to the requirements of this ... Stairways serving an
occupant load of more than 50 shall be not less in width than forty - four inches (
44 " ) .
Page 131
Stairway and ramp enclosures shall include landings and parts of floors
connecting stairway Alights and also shall ... A stairway in an exit enclosure shall
not continue below the grade level exit unless an approved barrier is provided at
the ...
Stairway and ramp enclosures shall include landings and parts of floors
connecting stairway Alights and also shall ... A stairway in an exit enclosure shall
not continue below the grade level exit unless an approved barrier is provided at
the ...
Page 134
Side exits shall open directly to a public way or into an exit court , approved
stairway , exterior stairway or exit passageway leading to a public way . Side
exits shall be accessible from a cross aisle . ( c ) Balcony Exits . Every balcony
having an ...
Side exits shall open directly to a public way or into an exit court , approved
stairway , exterior stairway or exit passageway leading to a public way . Side
exits shall be accessible from a cross aisle . ( c ) Balcony Exits . Every balcony
having an ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part Administrative | 11 |
Part 11Definitions and Abbreviations | 20 |
Part IIlRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood