Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 11
Page 137
... Stands . Stands employing combustible framing shall be limited to 11 rows or nine feet ( 9 ' ) in height . ( d ) Design Requirements . The minimum unit live load for reviewing stands , grandstands , and bleachers shall be 100 pounds per ...
... Stands . Stands employing combustible framing shall be limited to 11 rows or nine feet ( 9 ' ) in height . ( d ) Design Requirements . The minimum unit live load for reviewing stands , grandstands , and bleachers shall be 100 pounds per ...
Page 138
... stands with seats without backrests ; nine for open air stands with seats having backrests ; nine for seats without backrests within buildings , and six for seats with backrests in buildings . ( f ) Aisles . 1. Aisles required . Aisles ...
... stands with seats without backrests ; nine for open air stands with seats having backrests ; nine for seats without backrests within buildings , and six for seats with backrests in buildings . ( f ) Aisles . 1. Aisles required . Aisles ...
Page 139
International Conference of Building Officials. above grade . Where only sections of stands are used , guardrails Reviewing Stands , shall be provided as required in this Section . a seat Railings shall be forty - two inches ( 42 ...
International Conference of Building Officials. above grade . Where only sections of stands are used , guardrails Reviewing Stands , shall be provided as required in this Section . a seat Railings shall be forty - two inches ( 42 ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood