Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 16
Page 8
... Steel 1804 . Mortar 1805 . Masonry Units CHAPTER 19 . Foundations SEC . 1901 . General Requirements 1902 . Footings 1903. Foundation Ventilation , Durability , and Ter- mite Protection 88820 69 69 69 70 70 70 22 23 70 72 CHAPTER 20 ...
... Steel 1804 . Mortar 1805 . Masonry Units CHAPTER 19 . Foundations SEC . 1901 . General Requirements 1902 . Footings 1903. Foundation Ventilation , Durability , and Ter- mite Protection 88820 69 69 69 70 70 70 22 23 70 72 CHAPTER 20 ...
Page 69
... steel for concrete or masonry shall be as Reinforcing specified in Section 2601 and Section 2610 of the 1967 Edition of Steel the Uniform Building Code , Volume I. TABLE NO . 18 - A - NUMBER OF NAILS FOR CONNECTING WOOD MEMBERS Groups I ...
... steel for concrete or masonry shall be as Reinforcing specified in Section 2601 and Section 2610 of the 1967 Edition of Steel the Uniform Building Code , Volume I. TABLE NO . 18 - A - NUMBER OF NAILS FOR CONNECTING WOOD MEMBERS Groups I ...
Page 104
... Steel Wood 826 826 8 No. 9 gauge wire No. 8 gauge wire i " diameter , mild steel rod1 32 " diameter , mild steel rod1 1/4 " diameter , mild steel rod1 1 " x 1 " mild steel flats2 No. 12 gauge wire No. 10 gauge wire No. 8 gauge wire No ...
... Steel Wood 826 826 8 No. 9 gauge wire No. 8 gauge wire i " diameter , mild steel rod1 32 " diameter , mild steel rod1 1/4 " diameter , mild steel rod1 1 " x 1 " mild steel flats2 No. 12 gauge wire No. 10 gauge wire No. 8 gauge wire No ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood