Page 11
... stories in height or six thousand square feet ( 6000 sq . ft . ) in ground floor area . All other buildings and structures shall conform to all the provisions of the 1967 Edition of Volume I of the Uniform Building Code . EXCEPTION ...
... stories in height or six thousand square feet ( 6000 sq . ft . ) in ground floor area . All other buildings and structures shall conform to all the provisions of the 1967 Edition of Volume I of the Uniform Building Code . EXCEPTION ...
Page 53
... height , the limits specified in Sections 505 , 506 , and 507 . ( b ) Special Provisions . Group H Occupancies more than two stories in height or having more than three thousand square feet ( 3000 sq . ft . ) of floor area above the ...
... height , the limits specified in Sections 505 , 506 , and 507 . ( b ) Special Provisions . Group H Occupancies more than two stories in height or having more than three thousand square feet ( 3000 sq . ft . ) of floor area above the ...
Page 55
... stories in height the minimum width of the yard shall be increased at the rate of one foot ( 1 ′ ) for each additional story . For buildings exceeding 14 stories in height , the required width of yard shall be computed on the basis of ...
... stories in height the minimum width of the yard shall be increased at the rate of one foot ( 1 ′ ) for each additional story . For buildings exceeding 14 stories in height , the required width of yard shall be computed on the basis of ...
Contents
Part IAdministrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet 1 hour feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches G Occupancies gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles