Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 44
Page 29
... story . ( c ) Buildings on Same Property and Buildings Containing Courts . For the purpose of determining the ... story Areas . The area of a one - story building Allowable shall not exceed the limits set forth in Table No. 5 - C except ...
... story . ( c ) Buildings on Same Property and Buildings Containing Courts . For the purpose of determining the ... story Areas . The area of a one - story building Allowable shall not exceed the limits set forth in Table No. 5 - C except ...
Page 53
... story in Group H Occupancies provided : 1. The first story is of Type I construction with no basement or cellar below and is limited in area to that of the floor immediately above , except where approved access to the stories above is ...
... story in Group H Occupancies provided : 1. The first story is of Type I construction with no basement or cellar below and is limited in area to that of the floor immediately above , except where approved access to the stories above is ...
Page 55
... story and two - story buildings . For buildings more than two stories in height the minimum width of the yard shall be increased at the rate of one foot ( 1 ' ) for each additional story . For buildings exceeding 14 stories in height ...
... story and two - story buildings . For buildings more than two stories in height the minimum width of the yard shall be increased at the rate of one foot ( 1 ' ) for each additional story . For buildings exceeding 14 stories in height ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles