... strips attached to the studs . Wood shingles or shakes may be applied over fiberboard shingle backer and sheathing with annular grooved nails . The thickness of wood shingles or shakes between wood nailing boards shall be not less than ...
... strips attached to the studs . Wood shingles or shakes may be applied over fiberboard shingle backer and sheathing with annular grooved nails . The thickness of wood shingles or shakes between wood nailing boards shall be not less than ...
Page 84
... strip . Allowable uniform load based on de- flection of 1/360 of span is 100 pounds per square foot . May be sixteen - inch ( 16 " ) if twenty - five - thirty - seconds - inch ( 32 " ) wood strip flooring is installed at right angles to ...
... strip . Allowable uniform load based on de- flection of 1/360 of span is 100 pounds per square foot . May be sixteen - inch ( 16 " ) if twenty - five - thirty - seconds - inch ( 32 " ) wood strip flooring is installed at right angles to ...
Page 102
... strips not less than one - inch by two - inch ( 1 ′′ x 2 ′′ ) nominal dimension may be used over solid backing . ( c ) Studless Partitions . The minimum thickness of vertically erected studless solid plaster partitions of three ...
... strips not less than one - inch by two - inch ( 1 ′′ x 2 ′′ ) nominal dimension may be used over solid backing . ( c ) Studless Partitions . The minimum thickness of vertically erected studless solid plaster partitions of three ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles