Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 44
Page 12
... structure , such building or structure shall be made to conform to the requirements for new buildings or structures . ( c ) Additions , Alterations , and Repairs : 25 to 50 Per Cent . Additions , alterations , and repairs exceeding 25 ...
... structure , such building or structure shall be made to conform to the requirements for new buildings or structures . ( c ) Additions , Alterations , and Repairs : 25 to 50 Per Cent . Additions , alterations , and repairs exceeding 25 ...
Page 14
... structure is being used contrary to the provisions of this Code , the Building Official may order such use discontinued and the structure , or portion thereof , vacated by notice served on any person causing such use to be continued ...
... structure is being used contrary to the provisions of this Code , the Building Official may order such use discontinued and the structure , or portion thereof , vacated by notice served on any person causing such use to be continued ...
Page 15
... structure or portion thereof , the City Council may order the owner of the building prosecuted as a viola- tor of the provisions of this Code and may order the Building Offi- cial to proceed with the work specified in such notice . A ...
... structure or portion thereof , the City Council may order the owner of the building prosecuted as a viola- tor of the provisions of this Code and may order the Building Offi- cial to proceed with the work specified in such notice . A ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles