... stud . CHAPTER 20 - WALLS Sec . 2001. ( a ) Stud Walls and Bearing Partitions . 1. Placing . Studs in walls and partitions may be placed with their wide faces parallel to the wall or partition , provided the studs are considered as ...
... stud . CHAPTER 20 - WALLS Sec . 2001. ( a ) Stud Walls and Bearing Partitions . 1. Placing . Studs in walls and partitions may be placed with their wide faces parallel to the wall or partition , provided the studs are considered as ...
Page 74
... stud , fitted snugly and spiked into the studs at their mid - height , or other means for giving ade- quate lateral support to the studs . Bridging meeting the require- ments of Section 2002 may serve as required firestopping . 12 ...
... stud , fitted snugly and spiked into the studs at their mid - height , or other means for giving ade- quate lateral support to the studs . Bridging meeting the require- ments of Section 2002 may serve as required firestopping . 12 ...
Page 119
... stud . Where required in Table No. 24 - I , blocking having the same cross - sectional dimensions as the studs shall be provided at all joints that are perpendicular to the studs . The size and spacing of nails shall be as set forth in ...
... stud . Where required in Table No. 24 - I , blocking having the same cross - sectional dimensions as the studs shall be provided at all joints that are perpendicular to the studs . The size and spacing of nails shall be as set forth in ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood