Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 21
Page 25
... surface of any floor and the upper surface of the floor next above , except that the topmost story shall be that portion of a building included between the upper surface of the topmost floor and the ceiling or roof above . If the ...
... surface of any floor and the upper surface of the floor next above , except that the topmost story shall be that portion of a building included between the upper surface of the topmost floor and the ceiling or roof above . If the ...
Page 71
... SURFACE OF GROUND AND FINISH GRADE ( Inches ) 12 2824 18 THICKNESS OF FOUNDATION WALL WIDTH OF THICKNESS OF FOOTING FOOTING ( Inches ) ( Inches ) ( Inches ) Unit Concrete Masonry 6 6 12 8 8 15 10 10 18 258 678 TABLE NO . 19 - B ...
... SURFACE OF GROUND AND FINISH GRADE ( Inches ) 12 2824 18 THICKNESS OF FOUNDATION WALL WIDTH OF THICKNESS OF FOOTING FOOTING ( Inches ) ( Inches ) ( Inches ) Unit Concrete Masonry 6 6 12 8 8 15 10 10 18 258 678 TABLE NO . 19 - B ...
Page 110
... surface leaving the surface rough to receive the finish coat . For three - coat work , the surface of the first coat shall be scored sufficiently to provide adequate bond for the second coat and shall be permitted to harden and set ...
... surface leaving the surface rough to receive the finish coat . For three - coat work , the surface of the first coat shall be scored sufficiently to provide adequate bond for the second coat and shall be permitted to harden and set ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles