Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 26
Page 14
... thereof , vacated by notice served on any person causing such use to be continued . Such person shall discontinue the use within 10 days after receipt of such notice or make the structure , or portion thereof , comply with the ...
... thereof , vacated by notice served on any person causing such use to be continued . Such person shall discontinue the use within 10 days after receipt of such notice or make the structure , or portion thereof , comply with the ...
Page 18
... thereof , to and including $ 2,000.00 $ 20.00 for the first $ 2,000.00 plus $ 3.00 for each additional thousand or fraction thereof , to and including $ 25,000.00 $ 89.00 for the first $ 25,000.00 plus $ 2.50 for each additional ...
... thereof , to and including $ 2,000.00 $ 20.00 for the first $ 2,000.00 plus $ 3.00 for each additional thousand or fraction thereof , to and including $ 25,000.00 $ 89.00 for the first $ 25,000.00 plus $ 2.50 for each additional ...
Page 22
... thereof issued by an approved agency having a re - examina- tion service . FLOOR AREA is the area included within the surrounding exte- rior walls of a building or portion thereof , exclusive of vent shafts and courts . The floor area ...
... thereof issued by an approved agency having a re - examina- tion service . FLOOR AREA is the area included within the surrounding exte- rior walls of a building or portion thereof , exclusive of vent shafts and courts . The floor area ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles