Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 25
Page 83
... thickness in place of not less than nineteen thirty- seconds inch ( 43 " ) and shall have a minimum thickness of not less than three - eighths inch ( % " ) . Bevel siding shall have a minimum thickness measured at the butt section of ...
... thickness in place of not less than nineteen thirty- seconds inch ( 43 " ) and shall have a minimum thickness of not less than three - eighths inch ( % " ) . Bevel siding shall have a minimum thickness measured at the butt section of ...
Page 98
... thickness . In every case the corbeling shall not exceed one - inch ( 1 ′′ ) projection for each course of brick ... thickness . Walls of fireboxes shall be not less than ten inches ( 10 " ) in thickness , except that where a lining of ...
... thickness . In every case the corbeling shall not exceed one - inch ( 1 ′′ ) projection for each course of brick ... thickness . Walls of fireboxes shall be not less than ten inches ( 10 " ) in thickness , except that where a lining of ...
Page 109
International Conference of Building Officials. TABLE NO . 24 - D - THICKNESS OF PLASTER ' FINISHED THICKNESS OF PLASTER FROM FACE OF LATH , MASONRY , CONCRETE % " maximum 1For Fire - resistive Construction , see Tables No. 43 - A , No ...
International Conference of Building Officials. TABLE NO . 24 - D - THICKNESS OF PLASTER ' FINISHED THICKNESS OF PLASTER FROM FACE OF LATH , MASONRY , CONCRETE % " maximum 1For Fire - resistive Construction , see Tables No. 43 - A , No ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles