Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 24
Page 56
... unit in excess of two . 2. The unit shall be provided with a separate closet . 3. The unit shall be provided with a kitchen sink , cooking ap- pliance and refrigeration facilities each having a clear working space of not less than ...
... unit in excess of two . 2. The unit shall be provided with a separate closet . 3. The unit shall be provided with a kitchen sink , cooking ap- pliance and refrigeration facilities each having a clear working space of not less than ...
Page 76
... Unit Masonry 18 Solid Masonry 20 Grouted Masonry 20 Reinforced Grouted Masonry 25 Reinforced Hollow Unit Masonry 25 NONBEARING WALLS : Exterior Unreinforced Walls 20 Exterior Reinforced Walls Interior Partitions Unreinforced Interior ...
... Unit Masonry 18 Solid Masonry 20 Grouted Masonry 20 Reinforced Grouted Masonry 25 Reinforced Hollow Unit Masonry 25 NONBEARING WALLS : Exterior Unreinforced Walls 20 Exterior Reinforced Walls Interior Partitions Unreinforced Interior ...
Page 77
... unit metal ties or cross wires of masonry joint reinforcement conforming to the requirements of Section 2008 ( b ) for cavity walls . Unit ties shall be of sufficient length to engage all wythes , with ends embedded not less than one ...
... unit metal ties or cross wires of masonry joint reinforcement conforming to the requirements of Section 2008 ( b ) for cavity walls . Unit ties shall be of sufficient length to engage all wythes , with ends embedded not less than one ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood