... vent ducts , piping , and shafting . All openings in exterior walls except wall vents shall be protected by a fire assembly having a three - fourths- hour fire - resistive rating . Such fire assemblies shall be fixed , auto- matic , or ...
... vent ducts , piping , and shafting . All openings in exterior walls except wall vents shall be protected by a fire assembly having a three - fourths- hour fire - resistive rating . Such fire assemblies shall be fixed , auto- matic , or ...
Page 65
... vents , ducts and piping in Groups H and I Occupancies not more than two stories in height need not be lined if the vents or ducts enclosed by the shaft are constructed of at least No. 26 galvanized sheet metal gauge and the shaft is ...
... vents , ducts and piping in Groups H and I Occupancies not more than two stories in height need not be lined if the vents or ducts enclosed by the shaft are constructed of at least No. 26 galvanized sheet metal gauge and the shaft is ...
Page 94
... vents with the balance of the required ven- tilation provided by eave or cornice vents . CHAPTER 23 CHIMNEYS , FIREPLACES AND BARBECUES - Sec . 2301. ( a ) General . Chimneys , flues and fireplaces and their connections , carrying ...
... vents with the balance of the required ven- tilation provided by eave or cornice vents . CHAPTER 23 CHIMNEYS , FIREPLACES AND BARBECUES - Sec . 2301. ( a ) General . Chimneys , flues and fireplaces and their connections , carrying ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles