TIE WIRE is wire for securing together metal framing or supports , for tying metal
and wire lath and gypsum lath and wallboard together and for securing
accessories . WIRE BACKING is horizontal strands of tautened wire attached to
surfaces ...
TIE WIRE is wire for securing together metal framing or supports , for tying metal
and wire lath and gypsum lath and wallboard together and for securing
accessories . WIRE BACKING is horizontal strands of tautened wire attached to
surfaces ...
Page 114
24 - G - APPLICATION OF SINGLE - PLY GYPSUM WALLBOARD Fastening
Required with Adhesive Application Horizontal Either Direction Perpendicular
Either Direction As required for 12 " and 58 " gypsum wallboard , see above ...
24 - G - APPLICATION OF SINGLE - PLY GYPSUM WALLBOARD Fastening
Required with Adhesive Application Horizontal Either Direction Perpendicular
Either Direction As required for 12 " and 58 " gypsum wallboard , see above ...
Page 116
Gypsum Wallboard ( b ) Supports . Supports shall be spaced not to exceed the
spac( Continued ) ing set forth in Table No . 24 - G for single - ply application and
Table No . 24 - H for two - ply application . Vertical assemblies shall comply with ...
Gypsum Wallboard ( b ) Supports . Supports shall be spaced not to exceed the
spac( Continued ) ing set forth in Table No . 24 - G for single - ply application and
Table No . 24 - H for two - ply application . Vertical assemblies shall comply with ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part Administrative | 11 |
Part 11Definitions and Abbreviations | 20 |
Part IIlRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood