Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 37
Page 124
... Width and Height . Every required exit doorway shall be of a size as to permit the installation of a door not less than three feet ( 3 ' ) in width and not less than six feet eight inches ( 6′8 ′′ ) in height . When installed in exit ...
... Width and Height . Every required exit doorway shall be of a size as to permit the installation of a door not less than three feet ( 3 ' ) in width and not less than six feet eight inches ( 6′8 ′′ ) in height . When installed in exit ...
Page 128
... Width . Stairways serving an occupant load of more than 50 shall be not less in width than forty - four inches ( 44 ′′ ) . Stair- ways serving an occupant load of 50 or less may be thirty - six inches ( 36 " ) wide . Private stairways ...
... Width . Stairways serving an occupant load of more than 50 shall be not less in width than forty - four inches ( 44 ′′ ) . Stair- ways serving an occupant load of 50 or less may be thirty - six inches ( 36 " ) wide . Private stairways ...
Page 133
... Width . Every aisle shall be not less than three feet ( 3 ′ ) wide if serving only one side , and not less than three feet six inches ( 3'6 " ) wide if serving both sides . Such minimum width shall be measured at the point farthest from ...
... Width . Every aisle shall be not less than three feet ( 3 ′ ) wide if serving only one side , and not less than three feet six inches ( 3'6 " ) wide if serving both sides . Such minimum width shall be measured at the point farthest from ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles