Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 13
Page 101
... wire fabric not less than three inches ( 3 ′′ ) wide to be installed as re- quired over joints of gypsum lath . TIE WIRE is wire for securing together metal framing or sup- ports , for tying metal and wire lath and gypsum lath and ...
... wire fabric not less than three inches ( 3 ′′ ) wide to be installed as re- quired over joints of gypsum lath . TIE WIRE is wire for securing together metal framing or sup- ports , for tying metal and wire lath and gypsum lath and ...
Page 104
... Wire Loops at Beams or Joists3 12 16 For Supporting Runners For Supporting Furring without Runners3 ( Wire Loops at Supports ) Type of Support : Concrete Steel Wood 826 826 8 No. 9 gauge wire No. 8 gauge wire i " diameter , mild steel ...
... Wire Loops at Beams or Joists3 12 16 For Supporting Runners For Supporting Furring without Runners3 ( Wire Loops at Supports ) Type of Support : Concrete Steel Wood 826 826 8 No. 9 gauge wire No. 8 gauge wire i " diameter , mild steel ...
Page 110
... wire lath and portland cement plaster . Backing is not required under metal lath or paperbacked wire lath . ( d ) Weather Protection . Building paper shall be installed as required in Section 1707 ( a ) . ( e ) Application of Metal ...
... wire lath and portland cement plaster . Backing is not required under metal lath or paperbacked wire lath . ( d ) Weather Protection . Building paper shall be installed as required in Section 1707 ( a ) . ( e ) Application of Metal ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof portland cement plaster pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles