Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 13
Page 101
... wire fabric not less than three inches ( 3 ′′ ) wide to be installed as re- quired over joints of gypsum lath . TIE WIRE is wire for securing together metal framing or sup- ports , for tying metal and wire lath and gypsum lath and ...
... wire fabric not less than three inches ( 3 ′′ ) wide to be installed as re- quired over joints of gypsum lath . TIE WIRE is wire for securing together metal framing or sup- ports , for tying metal and wire lath and gypsum lath and ...
Page 104
... wire No. 10 gauge wire No. 8 gauge wire TABLE NO . 24 - A - SUSPENDED AND FURRED. Hangers for Suspended Ceilings 12.5 16 18 20 22.5 25.0 12 16 826826 Hangers for Attaching Runners and Furring Di- rectly to Beams and Joists For Supporting ...
... wire No. 10 gauge wire No. 8 gauge wire TABLE NO . 24 - A - SUSPENDED AND FURRED. Hangers for Suspended Ceilings 12.5 16 18 20 22.5 25.0 12 16 826826 Hangers for Attaching Runners and Furring Di- rectly to Beams and Joists For Supporting ...
Page 107
... Wire Lath 1.95 pounds , No. 11 gauge , 2 " x 2 " 1.4 pounds , No. 16 gauge , 2 " x 2 " 1.4 pounds , No. 18 gauge , 1 ′′ x 1 ′′ 6 24 24 16 2295 24 24 24 16 16 16 1 € 163 Woven 1.4 pounds , No. 17 gauge , 11⁄2 " Hexagon 1.4 pounds , No ...
... Wire Lath 1.95 pounds , No. 11 gauge , 2 " x 2 " 1.4 pounds , No. 16 gauge , 2 " x 2 " 1.4 pounds , No. 18 gauge , 1 ′′ x 1 ′′ 6 24 24 16 2295 24 24 24 16 16 16 1 € 163 Woven 1.4 pounds , No. 17 gauge , 11⁄2 " Hexagon 1.4 pounds , No ...
Contents
Part IAdministrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
aisle applied approved Area Allowable Building Official building or structure cavity walls cent Chapter 23 coat combustible conform Continued corbeled corridors exceed exit doors exterior exit balcony exterior walls feet 1 hour feet Not permitted feet Protected less fire assembly Fire Zone Fire-extinguishing Systems fire-resistive rating fireplace Firestopping flammable liquids foot four inches G Occupancies gauge Group D Occupancies Group H grout Gypsum Lath gypsum wallboard horizontal hour less incombustible installed joists less than four Location on Property locking device Masonry chimneys materials maximum metal lath minimum nails occupant load one-hour fire-resistive construction partitions permitted less portion thereof pounds per square ramp seats sheathing shingles soffits space spans Special Hazards specified in Chapter specified in Section Stairs stairway stories in height studs supports surface Table thickness tion toilet twelve inches 12 types of construction U.B.C. Standard Uniform Building Code veneer Ventilation Vertical Openings Wood shingles