... wire fabric not less than three inches ( 3 ′′ ) wide to be installed as re- quired over joints of gypsum lath . TIE WIRE is wire for securing together metal framing or sup- ports , for tying metal and wire lath and gypsum lath and ...
... wire fabric not less than three inches ( 3 ′′ ) wide to be installed as re- quired over joints of gypsum lath . TIE WIRE is wire for securing together metal framing or sup- ports , for tying metal and wire lath and gypsum lath and ...
Page 104
... Wire Loops at Beams or Joists3 12 16 For Supporting Runners For Supporting Furring without Runners3 ( Wire Loops at Supports ) Type of Support : Concrete Steel Wood 826 826 8 No. 9 gauge wire No. 8 gauge wire i " diameter , mild steel ...
... Wire Loops at Beams or Joists3 12 16 For Supporting Runners For Supporting Furring without Runners3 ( Wire Loops at Supports ) Type of Support : Concrete Steel Wood 826 826 8 No. 9 gauge wire No. 8 gauge wire i " diameter , mild steel ...
Page 110
... wire lath and portland cement plaster . Backing is not required under metal lath or paperbacked wire lath . ( d ) Weather Protection . Building paper shall be installed as required in Section 1707 ( a ) . ( e ) Application of Metal ...
... wire lath and portland cement plaster . Backing is not required under metal lath or paperbacked wire lath . ( d ) Weather Protection . Building paper shall be installed as required in Section 1707 ( a ) . ( e ) Application of Metal ...
Contents
Part Administrative | 11 |
Part IIDefinitions and Abbreviations | 20 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood