Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 13
Page 101
STRIPPING is flat reinforcing units of expanded metal or wire fabric not less than
three inches ( 3 " ) wide to be installed as required over joints of gypsum lath . TIE
WIRE is wire for securing together metal framing or supports , for tying metal ...
STRIPPING is flat reinforcing units of expanded metal or wire fabric not less than
three inches ( 3 " ) wide to be installed as required over joints of gypsum lath . TIE
WIRE is wire for securing together metal framing or supports , for tying metal ...
Page 104
24 - A - SUSPENDED AND FURRED CEILINGS ( For Support of Ceilings
Weighing Not More than 10 Pounds per Square Foot ) Minimum Sizes for Wire
and Rigid Hangers SIZE AND TYPE MAXIMUM AREA SUPPORTED ( In Square
Feet ) ...
24 - A - SUSPENDED AND FURRED CEILINGS ( For Support of Ceilings
Weighing Not More than 10 Pounds per Square Foot ) Minimum Sizes for Wire
and Rigid Hangers SIZE AND TYPE MAXIMUM AREA SUPPORTED ( In Square
Feet ) ...
Page 110
Gypsum lath or gypsum board shall not be used , except that on horizontal
supports of ceilings or roof soffits , it may be used as backing for metal lath or wire
lath and portland cement plaster . Backing is not required under metal lath or ...
Gypsum lath or gypsum board shall not be used , except that on horizontal
supports of ceilings or roof soffits , it may be used as backing for metal lath or wire
lath and portland cement plaster . Backing is not required under metal lath or ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part Administrative | 11 |
Part 11Definitions and Abbreviations | 20 |
Part IIlRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood