Uniform Building Code, Volume 7International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 35
Page 64
Wood panels or similar light construction up to three - fourths the height of the
room in which placed ; when more than threefourths the height of the room , such
partitions shall have not less than the upper one - fourth of the partition
constructed ...
Wood panels or similar light construction up to three - fourths the height of the
room in which placed ; when more than threefourths the height of the room , such
partitions shall have not less than the upper one - fourth of the partition
constructed ...
Page 92
Each wood shingle shall be fastened to the sheathing with two nails only .
Shingles shall not be installed on a roof having a slope less than four inches ( 4 "
) to twelve inches ( 12 " ) unless they are installed over an underlay of not less
than 15 ...
Each wood shingle shall be fastened to the sheathing with two nails only .
Shingles shall not be installed on a roof having a slope less than four inches ( 4 "
) to twelve inches ( 12 " ) unless they are installed over an underlay of not less
than 15 ...
Page 102
EXCEPTION : Wood framed assemblies meeting the requirements of Section
2507 need not be designed ( b ) Wood Framing . Wood supports for lath or
gypsum wallboard shall be not less than two inches ( 2 " ) nominal in least
dimension .
EXCEPTION : Wood framed assemblies meeting the requirements of Section
2507 need not be designed ( b ) Wood Framing . Wood supports for lath or
gypsum wallboard shall be not less than two inches ( 2 " ) nominal in least
dimension .
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Part Administrative | 11 |
Part 11Definitions and Abbreviations | 20 |
Part IIlRequirements Based on Occupancy | 27 |
Copyright | |
Other editions - View all
Common terms and phrases
additional aisle Allowable applied approved assembly backing Building Official building or structure ceiling cement cent Chapter chimney coat concrete conform construction Continued corridors covering defined designed Division doors Edition enclosed Enclosure exceed EXCEPTION exit exterior walls finish Fire Zone fire-resistive construction floor floor area foot foundation four framing gauge grade ground Group grout gypsum height horizontal hour inches incombustible increased installed interior joints lath least less limits located masonry materials maximum metal nails occupant load one-hour openings partitions permitted persons placed plaster portion pounds protected repair resistance roof seats separation serving sheathing side solid space spans Special specified in Section square feet Stairs stairway Standard stands story structure studs supports surface Table thereof thickness tion Type Uniform Building Code units unless veneer Ventilation vertical Volume wallboard width wire wood