California Building Code, Volume 1International Conference of Building Officials, 2001 - Building laws |
From inside the book
Results 1-3 of 65
Page 1-83
... applied full length vertically , second layer applied horizontally or vertically . 2 " by 4 " ( 51 mm by 102 mm ) wood studs 16 " ( 406 mm ) on center with two layers 1 / 2 " ( 12.7 mm ) regular gypsum wallboard applied vertically or ...
... applied full length vertically , second layer applied horizontally or vertically . 2 " by 4 " ( 51 mm by 102 mm ) wood studs 16 " ( 406 mm ) on center with two layers 1 / 2 " ( 12.7 mm ) regular gypsum wallboard applied vertically or ...
Page 1-263
... applied over metal lath or wire fabric lath and shall not be less than two coats when applied over other bases permitted by this chapter . Showers and public toilet walls shall conform to Section 807.1 . Plaster shall not be applied ...
... applied over metal lath or wire fabric lath and shall not be less than two coats when applied over other bases permitted by this chapter . Showers and public toilet walls shall conform to Section 807.1 . Plaster shall not be applied ...
Page 6
... applied over an existing asphalt or wood shingle roof . Asphalt shingles applied over wood shingles shall not have less than Type 30 nonperforated felt underlayment installed prior to reroofing . 2. Wood shakes . Not more than one ...
... applied over an existing asphalt or wood shingle roof . Asphalt shingles applied over wood shingles shall not have less than Type 30 nonperforated felt underlayment installed prior to reroofing . 2. Wood shakes . Not more than one ...
Contents
Matrix Adoption Tables | XTC-1 |
UBC Standard 233 | XTC-23 |
UBC Standard 21 Noncombustible MaterialTests | 1-11 |
Copyright | |
11 other sections not shown
Other editions - View all
Common terms and phrases
2001 CALIFORNIA BUILDING 30 inches A L CL A L accessible route aisle AL CL AL applied approved assembly ASTM braced wall lines building official building or structure CALIFORNIA BUILDING CODE ceiling cement Chapter 11A CL AL CL CL CL comply with Section concrete corridors curb ramps Division door DOSH DSA/AC dwelling units elevator enclosure equipment exceed EXCEPTION exit exterior walls facilities fire-resistive rating fixture floor area gage gypsum handrails height installed joists LA LC LA lath LC LA LC LC LC less located masonry materials maximum means of egress minimum nails noncombustible occupant load openings OSHPD panels percent permitted plaster protected ramp regulations reinforcement requirements of Section roof rooms seating Select Structural side slope smoke square feet stairways storage studs surface Table thickness tion toilet Type UBC Standard Uniform Building Code veneer water closet wheelchair wire wood