... comply with this section . 4. Floor electrical receptacles . 5. Plumbing fixture controls . 1106.3.2 Clear floor space . A 30 - inch - by - 48 - inch ( 762 mm by 1219 mm ) minimum clear floor space positioned for forward or parallel ...
... comply with this section . 4. Floor electrical receptacles . 5. Plumbing fixture controls . 1106.3.2 Clear floor space . A 30 - inch - by - 48 - inch ( 762 mm by 1219 mm ) minimum clear floor space positioned for forward or parallel ...
Page 8
... comply with this section . L C LA LC LA LA 1134A.2 Number of Complying Bathrooms . Bathrooms shall be Lĉ designed to comply with one of the following options : LA L C Option 1. All bathrooms within the dwelling unit shall be de- Csigned ...
... comply with this section . L C LA LC LA LA 1134A.2 Number of Complying Bathrooms . Bathrooms shall be Lĉ designed to comply with one of the following options : LA L C Option 1. All bathrooms within the dwelling unit shall be de- Csigned ...
Page 1-29
... Section 1111B.4.2 L C to comply with this section , additional sleeping rooms and suites shall be provided with the following features in conformance with Table 11B - 4 and as follows : LA LC LC LA 1111B.4.5.1 Visual alarms . Auxiliary ...
... Section 1111B.4.2 L C to comply with this section , additional sleeping rooms and suites shall be provided with the following features in conformance with Table 11B - 4 and as follows : LA LC LC LA 1111B.4.5.1 Visual alarms . Auxiliary ...
Contents
Matrix Adoption Tables | XTC-1 |
UBC Standard 233 | XTC-23 |
UBC Standard 21 Noncombustible MaterialTests | 1-11 |
Copyright | |
11 other sections not shown
Other editions - View all
Common terms and phrases
2001 CALIFORNIA BUILDING 30 inches A L CL A L accessible route aisle AL CL AL applied approved assembly ASTM braced wall lines building official building or structure CALIFORNIA BUILDING CODE ceiling cement Chapter 11A CL AL CL CL CL comply with Section concrete corridors curb ramps Division door DOSH DSA/AC dwelling units elevator enclosure equipment exceed EXCEPTION exit exterior walls facilities fire-resistive rating fixture floor area gage gypsum handrails height installed joists LA LC LA lath LC LA LC LC LC less located masonry materials maximum means of egress minimum nails noncombustible occupant load openings OSHPD panels percent permitted plaster protected ramp regulations reinforcement requirements of Section roof rooms seating Select Structural side slope smoke square feet stairways storage studs surface Table thickness tion toilet Type UBC Standard Uniform Building Code veneer water closet wheelchair wire wood