California Building Code, Volume 1International Conference of Building Officials, 2001 - Building laws |
From inside the book
Results 1-3 of 88
Page 1-118
... enclosure . Exit enclosures shall be contin- uous and fully enclose all portions of the stairway or ramp to include parts of floors connecting stairway flights . Exit enclosures shall exit directly to the exterior of the building or ...
... enclosure . Exit enclosures shall be contin- uous and fully enclose all portions of the stairway or ramp to include parts of floors connecting stairway flights . Exit enclosures shall exit directly to the exterior of the building or ...
Page 1-7
... ENCLOSURE OF POOL AREA 3118B.1 Enclosure . The pool shall be enclosed by one or a com- bination of the following : a fence , portion of a building , wall or other approved durable enclosure . Doors , openable windows , or gates of ...
... ENCLOSURE OF POOL AREA 3118B.1 Enclosure . The pool shall be enclosed by one or a com- bination of the following : a fence , portion of a building , wall or other approved durable enclosure . Doors , openable windows , or gates of ...
Page 12
... enclosure construction . For floor open- ings that are enclosed by existing shaft enclosure construction having fire - resistive capabilities similar to wood lath and plaster in good condition , 1 / 2 - inch ( 12.7 mm ) gypsum wallboard ...
... enclosure construction . For floor open- ings that are enclosed by existing shaft enclosure construction having fire - resistive capabilities similar to wood lath and plaster in good condition , 1 / 2 - inch ( 12.7 mm ) gypsum wallboard ...
Contents
Matrix Adoption Tables | XTC-1 |
UBC Standard 233 | XTC-23 |
UBC Standard 21 Noncombustible MaterialTests | 1-11 |
Copyright | |
11 other sections not shown
Other editions - View all
Common terms and phrases
2001 CALIFORNIA BUILDING 30 inches A L CL A L accessible route aisle AL CL AL applied approved assembly ASTM braced wall lines building official building or structure CALIFORNIA BUILDING CODE ceiling cement Chapter 11A CL AL CL CL CL comply with Section concrete corridors curb ramps Division door DOSH DSA/AC dwelling units elevator enclosure equipment exceed EXCEPTION exit exterior walls facilities fire-resistive rating fixture floor area gage gypsum handrails height installed joists LA LC LA lath LC LA LC LC LC less located masonry materials maximum means of egress minimum nails noncombustible occupant load openings OSHPD panels percent permitted plaster protected ramp regulations reinforcement requirements of Section roof rooms seating Select Structural side slope smoke square feet stairways storage studs surface Table thickness tion toilet Type UBC Standard Uniform Building Code veneer water closet wheelchair wire wood