California Building Code, Volume 1International Conference of Building Officials, 2001 - Building laws |
From inside the book
Results 1-3 of 12
Page 1-78
... flange and providing not less than 0.025 square inch of steel area per foot ( 53 mm2 of steel area per meter ) in each direction . Siliceous aggregate concrete and concrete excluded in Item 2-1.1 with 3 " ( 76 mm ) or finer metal mesh ...
... flange and providing not less than 0.025 square inch of steel area per foot ( 53 mm2 of steel area per meter ) in each direction . Siliceous aggregate concrete and concrete excluded in Item 2-1.1 with 3 " ( 76 mm ) or finer metal mesh ...
Page 1-175
... flange or the web , and the flange widths shall not be less than 80 percent of the depth of the section . 2. The nominal depth in the direction of the web shall not be less than 8 inches ( 203 mm ) . 3. Flanges and webs shall have a ...
... flange or the web , and the flange widths shall not be less than 80 percent of the depth of the section . 2. The nominal depth in the direction of the web shall not be less than 8 inches ( 203 mm ) . 3. Flanges and webs shall have a ...
Page 1-263
... flange , and the exterior lath shall cover and terminate on the attachment flange of the screed . SECTION 2507 — INTERIOR PLASTER 2507.1 General . Plastering with gypsum plaster or cement plas- ter shall not be less than three coats ...
... flange , and the exterior lath shall cover and terminate on the attachment flange of the screed . SECTION 2507 — INTERIOR PLASTER 2507.1 General . Plastering with gypsum plaster or cement plas- ter shall not be less than three coats ...
Contents
Matrix Adoption Tables | XTC-1 |
UBC Standard 233 | XTC-23 |
UBC Standard 21 Noncombustible MaterialTests | 1-11 |
Copyright | |
11 other sections not shown
Other editions - View all
Common terms and phrases
2001 CALIFORNIA BUILDING 30 inches A L CL A L accessible route aisle AL CL AL applied approved assembly ASTM braced wall lines building official building or structure CALIFORNIA BUILDING CODE ceiling cement Chapter 11A CL AL CL CL CL comply with Section concrete corridors curb ramps Division door DOSH DSA/AC dwelling units elevator enclosure equipment exceed EXCEPTION exit exterior walls facilities fire-resistive rating fixture floor area gage gypsum handrails height installed joists LA LC LA lath LC LA LC LC LC less located masonry materials maximum means of egress minimum nails noncombustible occupant load openings OSHPD panels percent permitted plaster protected ramp regulations reinforcement requirements of Section roof rooms seating Select Structural side slope smoke square feet stairways storage studs surface Table thickness tion toilet Type UBC Standard Uniform Building Code veneer water closet wheelchair wire wood