California Building Code, Volume 1International Conference of Building Officials, 2001 - Building laws |
From inside the book
Results 1-3 of 88
Page 1-14
... floor area in Type I facilities and 70 square feet ( 6.5 m2 ) of floor area in Type II and Type III facilities ; 3. Have a minimum clear ceiling height of 8 feet ( 2438 mm ) and a minimum width of 6 feet ( 1829 mm ) ; 4. Contain a ...
... floor area in Type I facilities and 70 square feet ( 6.5 m2 ) of floor area in Type II and Type III facilities ; 3. Have a minimum clear ceiling height of 8 feet ( 2438 mm ) and a minimum width of 6 feet ( 1829 mm ) ; 4. Contain a ...
Page 1-52
... floor area not exceeding 2,500 square feet ( 232 m2 ) may have exterior - bearing walls of not less than two- hour fire - resistive construction when less than 5 feet ( 1524 mm ) from a property line , and not less than one hour when ...
... floor area not exceeding 2,500 square feet ( 232 m2 ) may have exterior - bearing walls of not less than two- hour fire - resistive construction when less than 5 feet ( 1524 mm ) from a property line , and not less than one hour when ...
Page 1-208
... floor Clearance . When wood joists or the bot- tom of wood structural floors ... floor assembly , including posts , girders , joists and subfloor , shall be ... area shall be accessible . Accessible under - floor areas shall be provided ...
... floor Clearance . When wood joists or the bot- tom of wood structural floors ... floor assembly , including posts , girders , joists and subfloor , shall be ... area shall be accessible . Accessible under - floor areas shall be provided ...
Contents
Matrix Adoption Tables | XTC-1 |
UBC Standard 233 | XTC-23 |
UBC Standard 21 Noncombustible MaterialTests | 1-11 |
Copyright | |
11 other sections not shown
Other editions - View all
Common terms and phrases
2001 CALIFORNIA BUILDING 30 inches A L CL A L accessible route aisle AL CL AL applied approved assembly ASTM braced wall lines building official building or structure CALIFORNIA BUILDING CODE ceiling cement Chapter 11A CL AL CL CL CL comply with Section concrete corridors curb ramps Division door DOSH DSA/AC dwelling units elevator enclosure equipment exceed EXCEPTION exit exterior walls facilities fire-resistive rating fixture floor area gage gypsum handrails height installed joists LA LC LA lath LC LA LC LC LC less located masonry materials maximum means of egress minimum nails noncombustible occupant load openings OSHPD panels percent permitted plaster protected ramp regulations reinforcement requirements of Section roof rooms seating Select Structural side slope smoke square feet stairways storage studs surface Table thickness tion toilet Type UBC Standard Uniform Building Code veneer water closet wheelchair wire wood