California Building Code, Volume 1International Conference of Building Officials, 2001 - Building laws |
From inside the book
Results 1-3 of 22
Page 1-189
... Lateral reinforcement requirements for composite compression members shall ... support provided by the corner of a tie with an included angle of not more ... Lateral Reinforcement for Flexural Members . 1907.11.1 Compression reinforcement ...
... Lateral reinforcement requirements for composite compression members shall ... support provided by the corner of a tie with an included angle of not more ... Lateral Reinforcement for Flexural Members . 1907.11.1 Compression reinforcement ...
Page 1-199
... Lateral Support . Masonry walls shall be laterally sup- ported in either the horizontal or vertical direction not exceeding the intervals set forth in Table 21 - O . Lateral support shall be provided by cross walls , pilasters , but ...
... Lateral Support . Masonry walls shall be laterally sup- ported in either the horizontal or vertical direction not exceeding the intervals set forth in Table 21 - O . Lateral support shall be provided by cross walls , pilasters , but ...
Page 1-200
... lateral support to masonry walls shall be connected to the masonry walls by one of the following methods : 1. Wood floor joists bearing on masonry walls shall be anchored to the wall by approved metal strap anchors at intervals not ...
... lateral support to masonry walls shall be connected to the masonry walls by one of the following methods : 1. Wood floor joists bearing on masonry walls shall be anchored to the wall by approved metal strap anchors at intervals not ...
Contents
Matrix Adoption Tables | XTC-1 |
UBC Standard 233 | XTC-23 |
UBC Standard 21 Noncombustible MaterialTests | 1-11 |
Copyright | |
11 other sections not shown
Other editions - View all
Common terms and phrases
2001 CALIFORNIA BUILDING 30 inches A L CL A L accessible route aisle AL CL AL applied approved assembly ASTM braced wall lines building official building or structure CALIFORNIA BUILDING CODE ceiling cement Chapter 11A CL AL CL CL CL comply with Section concrete corridors curb ramps Division door DOSH DSA/AC dwelling units elevator enclosure equipment exceed EXCEPTION exit exterior walls facilities fire-resistive rating fixture floor area gage gypsum handrails height installed joists LA LC LA lath LC LA LC LC LC less located masonry materials maximum means of egress minimum nails noncombustible occupant load openings OSHPD panels percent permitted plaster protected ramp regulations reinforcement requirements of Section roof rooms seating Select Structural side slope smoke square feet stairways storage studs surface Table thickness tion toilet Type UBC Standard Uniform Building Code veneer water closet wheelchair wire wood