California Building Code, Volume 1International Conference of Building Officials, 2001 - Building laws |
From inside the book
Results 1-3 of 92
Page 1-110
... Stairways . 1003.3.3.1 General . Every stairway having two or more risers serving any building or portion thereof shall comply with the requirements of Section 1003.3.3 . For the purposes of Section 1003.3.3 , the term " stairway ...
... Stairways . 1003.3.3.1 General . Every stairway having two or more risers serving any building or portion thereof shall comply with the requirements of Section 1003.3.3 . For the purposes of Section 1003.3.3 , the term " stairway ...
Page 1-111
... stairways in Group R , Division 3 Occupancies and within individual dwelling units of Group R , Division 1 Occupancies . The handgrip portion of handrails shall not be less than 1/4 inches ( 32 mm ) nor more than 2 inches ( 51 mm ) in ...
... stairways in Group R , Division 3 Occupancies and within individual dwelling units of Group R , Division 1 Occupancies . The handgrip portion of handrails shall not be less than 1/4 inches ( 32 mm ) nor more than 2 inches ( 51 mm ) in ...
Page 1-120
... stairways shall be made on a plane parallel and tangent to the stair tread nosings in the center of the stairway ... stairways . 1006.3.3.1 General . Exterior exit stairways serving as a portion of the exit discharge in the means of ...
... stairways shall be made on a plane parallel and tangent to the stair tread nosings in the center of the stairway ... stairways . 1006.3.3.1 General . Exterior exit stairways serving as a portion of the exit discharge in the means of ...
Contents
Matrix Adoption Tables | XTC-1 |
UBC Standard 233 | XTC-23 |
UBC Standard 21 Noncombustible MaterialTests | 1-11 |
Copyright | |
11 other sections not shown
Other editions - View all
Common terms and phrases
2001 CALIFORNIA BUILDING 30 inches A L CL A L accessible route aisle AL CL AL applied approved assembly ASTM braced wall lines building official building or structure CALIFORNIA BUILDING CODE ceiling cement Chapter 11A CL AL CL CL CL comply with Section concrete corridors curb ramps Division door DOSH DSA/AC dwelling units elevator enclosure equipment exceed EXCEPTION exit exterior walls facilities fire-resistive rating fixture floor area gage gypsum handrails height installed joists LA LC LA lath LC LA LC LC LC less located masonry materials maximum means of egress minimum nails noncombustible occupant load openings OSHPD panels percent permitted plaster protected ramp regulations reinforcement requirements of Section roof rooms seating Select Structural side slope smoke square feet stairways storage studs surface Table thickness tion toilet Type UBC Standard Uniform Building Code veneer water closet wheelchair wire wood