California Building Code, Volume 1International Conference of Building Officials, 2001 - Building laws |
From inside the book
Results 1-3 of 64
Page 1-80
... THICKNESS FACE - TO - FACE2 ( inches ) x 25.4 for mm MATERIAL ITEM NUMBER CONSTRUCTION 4 Hr . 3 Hr . 2 Hr . 1 Hr . 1 ... thickness , units at least 40 percent solid . Two cells in wall thickness , units at least 43 percent solid . Two ...
... THICKNESS FACE - TO - FACE2 ( inches ) x 25.4 for mm MATERIAL ITEM NUMBER CONSTRUCTION 4 Hr . 3 Hr . 2 Hr . 1 Hr . 1 ... thickness , units at least 40 percent solid . Two cells in wall thickness , units at least 43 percent solid . Two ...
Page 1-199
... thickness shall be the sums of the nominal thickness of the inner and outer wythes of the masonry . In walls composed of different classes of units and mortars , the ratio of height or length to thickness shall not exceed that allowed ...
... thickness shall be the sums of the nominal thickness of the inner and outer wythes of the masonry . In walls composed of different classes of units and mortars , the ratio of height or length to thickness shall not exceed that allowed ...
Page 6
... Thickness Equivalent Thickness Equivalent1 GALVANIZED SHEET Decimal and Nominal Thickness Equivalent Recommended Minimum Thickness Equivalent1 Manufacturer's Standard Galvanized Sheet Gage No. ( inch ) ( mm ) 2 ( inch ) ( mm ) 2 Gage No ...
... Thickness Equivalent Thickness Equivalent1 GALVANIZED SHEET Decimal and Nominal Thickness Equivalent Recommended Minimum Thickness Equivalent1 Manufacturer's Standard Galvanized Sheet Gage No. ( inch ) ( mm ) 2 ( inch ) ( mm ) 2 Gage No ...
Contents
Matrix Adoption Tables | XTC-1 |
UBC Standard 233 | XTC-23 |
UBC Standard 21 Noncombustible MaterialTests | 1-11 |
Copyright | |
11 other sections not shown
Other editions - View all
Common terms and phrases
2001 CALIFORNIA BUILDING 30 inches A L CL A L accessible route aisle AL CL AL applied approved assembly ASTM braced wall lines building official building or structure CALIFORNIA BUILDING CODE ceiling cement Chapter 11A CL AL CL CL CL comply with Section concrete corridors curb ramps Division door DOSH DSA/AC dwelling units elevator enclosure equipment exceed EXCEPTION exit exterior walls facilities fire-resistive rating fixture floor area gage gypsum handrails height installed joists LA LC LA lath LC LA LC LC LC less located masonry materials maximum means of egress minimum nails noncombustible occupant load openings OSHPD panels percent permitted plaster protected ramp regulations reinforcement requirements of Section roof rooms seating Select Structural side slope smoke square feet stairways storage studs surface Table thickness tion toilet Type UBC Standard Uniform Building Code veneer water closet wheelchair wire wood