California Building Code, Volume 1International Conference of Building Officials, 2001 - Building laws |
From inside the book
Results 1-3 of 15
Page 1-77
... Vermiculite concrete , 1 : 4 mix by volume over paperbacked wire fabric lath wrapped directly around column with additional 2 " by 2 " ( 51 mm by 51 mm ) 0.065 inch / 0.065 inch ( 1.65 mm / 1.65 mm ) ( No. 16/16 B. W. gage ) wire fabric ...
... Vermiculite concrete , 1 : 4 mix by volume over paperbacked wire fabric lath wrapped directly around column with additional 2 " by 2 " ( 51 mm by 51 mm ) 0.065 inch / 0.065 inch ( 1.65 mm / 1.65 mm ) ( No. 16/16 B. W. gage ) wire fabric ...
Page 1-87
... Vermiculite gypsum plaster on metallath attached to 3/4 " ( 19 mm ) cold - rolled channels with 0.049 inch ( 1.24 mm ) ( No. 21/210 18 B. W. gage ) wire ties spaced 6 ” ( 152 mm ) on center . Suspended ceiling of vermiculite gyp- sum ...
... Vermiculite gypsum plaster on metallath attached to 3/4 " ( 19 mm ) cold - rolled channels with 0.049 inch ( 1.24 mm ) ( No. 21/210 18 B. W. gage ) wire ties spaced 6 ” ( 152 mm ) on center . Suspended ceiling of vermiculite gyp- sum ...
Page 1-89
... Vermiculite concrete slab pro- portioned 1 : 4 ( portland cement to vermiculite aggregate ) on a 11/2 " -deep ( 38 mm ) steel deck supported on individually pro- tected steel framing . Maximum span of deck 6 ' 10 " ( 2083 mm ) where ...
... Vermiculite concrete slab pro- portioned 1 : 4 ( portland cement to vermiculite aggregate ) on a 11/2 " -deep ( 38 mm ) steel deck supported on individually pro- tected steel framing . Maximum span of deck 6 ' 10 " ( 2083 mm ) where ...
Contents
Matrix Adoption Tables | XTC-1 |
UBC Standard 233 | XTC-23 |
UBC Standard 21 Noncombustible MaterialTests | 1-11 |
Copyright | |
11 other sections not shown
Other editions - View all
Common terms and phrases
2001 CALIFORNIA BUILDING 30 inches A L CL A L accessible route aisle AL CL AL applied approved assembly ASTM braced wall lines building official building or structure CALIFORNIA BUILDING CODE ceiling cement Chapter 11A CL AL CL CL CL comply with Section concrete corridors curb ramps Division door DOSH DSA/AC dwelling units elevator enclosure equipment exceed EXCEPTION exit exterior walls facilities fire-resistive rating fixture floor area gage gypsum handrails height installed joists LA LC LA lath LC LA LC LC LC less located masonry materials maximum means of egress minimum nails noncombustible occupant load openings OSHPD panels percent permitted plaster protected ramp regulations reinforcement requirements of Section roof rooms seating Select Structural side slope smoke square feet stairways storage studs surface Table thickness tion toilet Type UBC Standard Uniform Building Code veneer water closet wheelchair wire wood