California Building Code, Volume 1International Conference of Building Officials, 2001 - Building laws |
From inside the book
Results 1-3 of 44
Page 1-133
... water closet are permitted to overlap the clear floor space . 2. Forward approach . 2.1 Sixty - six inches ( 1676 mm ) minimum , measured from the wall behind the water closet . 2.2 Forty - eight inches ( 1219 mm ) minimum , measured ...
... water closet are permitted to overlap the clear floor space . 2. Forward approach . 2.1 Sixty - six inches ( 1676 mm ) minimum , measured from the wall behind the water closet . 2.2 Forty - eight inches ( 1219 mm ) minimum , measured ...
Page 1
... water closet compart- ments designed for use by persons with disabilities , and the space immediately in front of a water closet compartment shall not be less than 48 inches ( 1219 mm ) as measured at right angles to compartment door in ...
... water closet compart- ments designed for use by persons with disabilities , and the space immediately in front of a water closet compartment shall not be less than 48 inches ( 1219 mm ) as measured at right angles to compartment door in ...
Page 1-34
... water closet compartment . A water closet fix- ture located in a compartment shall provide a minimum 28 inch- wide ( 711 mm ) clear space from a fixture or a minimum LA 32 inch - wide ( 813 mm ) clear space from a wall at one side of the ...
... water closet compartment . A water closet fix- ture located in a compartment shall provide a minimum 28 inch- wide ( 711 mm ) clear space from a fixture or a minimum LA 32 inch - wide ( 813 mm ) clear space from a wall at one side of the ...
Contents
Matrix Adoption Tables | XTC-1 |
UBC Standard 233 | XTC-23 |
UBC Standard 21 Noncombustible MaterialTests | 1-11 |
Copyright | |
11 other sections not shown
Other editions - View all
Common terms and phrases
2001 CALIFORNIA BUILDING 30 inches A L CL A L accessible route aisle AL CL AL applied approved assembly ASTM braced wall lines building official building or structure CALIFORNIA BUILDING CODE ceiling cement Chapter 11A CL AL CL CL CL comply with Section concrete corridors curb ramps Division door DOSH DSA/AC dwelling units elevator enclosure equipment exceed EXCEPTION exit exterior walls facilities fire-resistive rating fixture floor area gage gypsum handrails height installed joists LA LC LA lath LC LA LC LC LC less located masonry materials maximum means of egress minimum nails noncombustible occupant load openings OSHPD panels percent permitted plaster protected ramp regulations reinforcement requirements of Section roof rooms seating Select Structural side slope smoke square feet stairways storage studs surface Table thickness tion toilet Type UBC Standard Uniform Building Code veneer water closet wheelchair wire wood