Page 130
... requirements , the appropri- ate provisions of all other sections in this standard apply . UNIFORM BUILDING CODE STANDARD NO . 25-5 EASTERN WOODS , EASTERN WHITE PINE , RED PINE , EASTERN SPRUCE , BALSAM FIR , ASPEN ( BIGTOOTH QUAKING ) ...
... requirements , the appropri- ate provisions of all other sections in this standard apply . UNIFORM BUILDING CODE STANDARD NO . 25-5 EASTERN WOODS , EASTERN WHITE PINE , RED PINE , EASTERN SPRUCE , BALSAM FIR , ASPEN ( BIGTOOTH QUAKING ) ...
Page 1152
International Conference of Building Officials. UNIFORM BUILDING CODE STANDARD NO . 47-10 GYPSUM SHEATHING BOARD Based on Standard Specification C79-82a of the American Society for Testing and Materials See Chapter 60 , Uniform Building ...
International Conference of Building Officials. UNIFORM BUILDING CODE STANDARD NO . 47-10 GYPSUM SHEATHING BOARD Based on Standard Specification C79-82a of the American Society for Testing and Materials See Chapter 60 , Uniform Building ...
Page 1157
International Conference of Building Officials. UNIFORM BUILDING CODE STANDARD NO . 47-14 WATER - RESISTANT GYPSUM BACKING BOARD Based on Standard Specification C630-76 of the American Society for Testing and Materials Scope See Section ...
International Conference of Building Officials. UNIFORM BUILDING CODE STANDARD NO . 47-14 WATER - RESISTANT GYPSUM BACKING BOARD Based on Standard Specification C630-76 of the American Society for Testing and Materials Scope See Section ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone