Uniform Building Code Standards |
From inside the book
Results 1-3 of 75
Page 342
... allowable load may be determined by straight - line interpolation between zero and the tabulated load , except that penetration shall be not less than one third of that specified . Design values shall not be increased when the ...
... allowable load may be determined by straight - line interpolation between zero and the tabulated load , except that penetration shall be not less than one third of that specified . Design values shall not be increased when the ...
Page 344
... allowable loads determined by the provisions in this standard are for wood screws in seasoned lumber except as otherwise specifically provided . 2. Service condition . Allowable loads apply for joints used indoors or in a location ...
... allowable loads determined by the provisions in this standard are for wood screws in seasoned lumber except as otherwise specifically provided . 2. Service condition . Allowable loads apply for joints used indoors or in a location ...
Page 775
... allowable compressive stresses given in Specifications 9 , 15 , 16 , 18 and 19 of Table No. 28 - C of the Uniform ... allowable stresses for thin sections shall not exceed the value of Fab given by the following formulas : ALLOWABLE ...
... allowable compressive stresses given in Specifications 9 , 15 , 16 , 18 and 19 of Table No. 28 - C of the Uniform ... allowable stresses for thin sections shall not exceed the value of Fab given by the following formulas : ALLOWABLE ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone