Uniform Building Code Standards |
From inside the book
Results 1-3 of 77
Page 25
... approved manner in conformance with approved nationally recognized standards for fire alarm systems . It shall be properly identified or marked and protected to avoid interruption of service . ( c ) Condition of Approval . Prior to the ...
... approved manner in conformance with approved nationally recognized standards for fire alarm systems . It shall be properly identified or marked and protected to avoid interruption of service . ( c ) Condition of Approval . Prior to the ...
Page 921
... approved indicator post designed for use with an underground valve or an approved integral indicator post and valve shall be provided for the control of the water supply from a public water supply to a standpipe or combined system and ...
... approved indicator post designed for use with an underground valve or an approved integral indicator post and valve shall be provided for the control of the water supply from a public water supply to a standpipe or combined system and ...
Page 922
... approved means . Welding of joints may be approved . Permission for welded joints shall be obtained from the building official , and welding shall be done in the shop of an approved fabricator and approved welding fittings shall be ...
... approved means . Welding of joints may be approved . Permission for welded joints shall be obtained from the building official , and welding shall be done in the shop of an approved fabricator and approved welding fittings shall be ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone