Uniform Building Code Standards |
From inside the book
Results 1-3 of 63
Page 338
... bolts . Row of bolts means a number of bolts placed in a line parallel to the direction of the load when parallel or perpendicular to grain . 2. Parallel - to - grain loading . For parallel - to - grain loading , the minimum spacing is ...
... bolts . Row of bolts means a number of bolts placed in a line parallel to the direction of the load when parallel or perpendicular to grain . 2. Parallel - to - grain loading . For parallel - to - grain loading , the minimum spacing is ...
Page 682
... BOLTS Based on the Specification for Structural Joints Using ASTM A325 or A490 Bolts ( August 14 , 1980 ) as endorsed by the American Institute of Steel Construction , Inc. , and Industrial Fastening Institute See Section 2713 ( a ) and ...
... BOLTS Based on the Specification for Structural Joints Using ASTM A325 or A490 Bolts ( August 14 , 1980 ) as endorsed by the American Institute of Steel Construction , Inc. , and Industrial Fastening Institute See Section 2713 ( a ) and ...
Page 685
... bolts and galvanized A325 bolts shall not be reused . Other A325 bolts may be reused if approved by the building official . Retightening previously tightened bolts which may have been loosened by the tightening of adjacent bolts shall ...
... bolts and galvanized A325 bolts shall not be reused . Other A325 bolts may be reused if approved by the building official . Retightening previously tightened bolts which may have been loosened by the tightening of adjacent bolts shall ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone