Uniform Building Code Standards |
From inside the book
Results 1-3 of 73
Page 392
... compression flange . The actual stress in the compression flange shall not exceed the allowable stress established by the following formula and in no case shall exceed the allowable unit stress for compression parallel to the grain : PK ...
... compression flange . The actual stress in the compression flange shall not exceed the allowable stress established by the following formula and in no case shall exceed the allowable unit stress for compression parallel to the grain : PK ...
Page 712
... compression elements Cy = FIF F is defined in Section 27.914 and F is defined in Section 27.913 ( a ) ( 3 ) Multiple - stiffened compression elements and compression elements with edge stiffeners C , = 1 When applicable effective design ...
... compression elements Cy = FIF F is defined in Section 27.914 and F is defined in Section 27.913 ( a ) ( 3 ) Multiple - stiffened compression elements and compression elements with edge stiffeners C , = 1 When applicable effective design ...
Page 750
... compression that is permitted by this specification where bending stress only exists ( Sections 27.1007 , 27.1008 and 27.1009 ) , ksi . = maximum bending stress in compression permitted where bending stress only exists and the ...
... compression that is permitted by this specification where bending stress only exists ( Sections 27.1007 , 27.1008 and 27.1009 ) , ksi . = maximum bending stress in compression permitted where bending stress only exists and the ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone