... Compressive strength . Specimens shall be tested at ages of three , seven and 28 days , six months , and one year in accordance with Part IV , Compression Tests , of U.B.C. Standard No. 26-10 . The compressive strength of the concrete ...
... Compressive strength . Specimens shall be tested at ages of three , seven and 28 days , six months , and one year in accordance with Part IV , Compression Tests , of U.B.C. Standard No. 26-10 . The compressive strength of the concrete ...
Page 600
... strength gypsum plaster or sulfur mortar meeting the requirements set forth below : 1. High - strength gypsum ... Compressive strength ( aged two hours ) : min . , psi MN / m2 Composition : Combustible materials , percent Noncombustible ...
... strength gypsum plaster or sulfur mortar meeting the requirements set forth below : 1. High - strength gypsum ... Compressive strength ( aged two hours ) : min . , psi MN / m2 Composition : Combustible materials , percent Noncombustible ...
Page 1150
... compressive strength of not less than 400 psi . Ready - mixed plaster with vermiculite aggregate for use over porous masonry bases shall contain not more than 3 cubic feet of aggregate per 100 pounds of calcined gypsum plaster and shall ...
... compressive strength of not less than 400 psi . Ready - mixed plaster with vermiculite aggregate for use over porous masonry bases shall contain not more than 3 cubic feet of aggregate per 100 pounds of calcined gypsum plaster and shall ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone